Load Calculations

Residential, commercial, industrial, feeder, panel, service, appliance, HVAC, and EV load calculators.

What this group covers

Load Calculations groups 2 calculator topics and 62 individual calculators in total. The calculators answer 33 on load Accounting, 29 on capacity Margin, 26 on commercial Load, 26 on residential Load, 23 on demand Factor. Open a topic below for its calculators, formulas, and review notes.

Written for Electricians, Engineers, Estimators, Facility Teams, Inspectors, and Technicians.

Standards basis across the group: IEEE (1), NFPA 70 (NEC) (36).

Where to start a load calculation

A load calculation is an accounting exercise before it is an arithmetic one. The order that survives review is: collect the loads, decide which of them are continuous, apply the demand allowance the code edition allows for that load type, then compare the total against the capacity of the equipment already installed. Doing the demand step first, or sizing the service before the load list is complete, is how a schedule ends up reworked twice.

This group splits along occupancy, and the split matters. Residential load work starts from floor area, small-appliance and laundry circuits, and the named appliance loads, then adds the larger single loads a dwelling actually has: range, dryer, water heater, heat pump, EV charger. Commercial and industrial load work starts from the equipment list and the phase balance, because a three-phase feeder that is correct in total kVA can still be badly balanced across phases.

Both branches end at the same three questions, and it is worth answering them explicitly on the record: what is the connected load, what is the demand load after the allowed allowances, and what margin is left against the equipment rating. A panel schedule that only states the connected total has answered the least useful of the three.

The most common review finding is not a wrong demand factor; it is a load list that was never completed. A panel schedule that omits the future EV charger, the shop dust collector, or the second kitchen appliance is arithmetically correct and practically useless, because the service it sizes will not carry what the building actually installs later. Listing every load you know about, and marking the ones that are planned rather than present, costs a few minutes and prevents the rework.

Phase balance deserves its own line in the record on any three-phase panel. Connected kVA can be correct while one phase carries materially more than another, and the consequences show up later as a hot neutral, a nuisance trip, or a service that trips on a load that should fit. Note the per-phase totals next to the three-phase total rather than only the total.

Which topic to open first

  • Residential Load And Service

    Start here for a dwelling: floor area, appliance load, service size, panel schedule, EV charger, heat pump, and generator load.

  • Commercial And Industrial Loads

    Start here for a commercial or industrial feeder: phase balance, tenant load, kitchen and data-center load, and demand treatment.

Sub-topics in this group

Load Calculations resolves into 21 working sub-topics. The calculators behind them are listed on each topic page below rather than repeated here, and a calculator appears under every sub-topic it serves, so the counts overlap where one page answers more than one question.

  • Commercial And Industrial Loads 30

    Three-phase load balance, feeder load, panel schedules, kitchen loads, data-center loads, and industrial demand.

    Serves Commercial Load (26), Line Current (18), Load Accounting (18).

    Commercial and industrial load workflows are preliminary arithmetic. Confirm phase balance, demand treatment, equipment data, protection, neutral effects, utility requirements, and adopted code before final design.

  • Residential Load And Service 32

    Dwelling load, panel load, service size, NEC 220 demand, EV charger, heat pump, and generator load calculators.

    Serves Residential Load (26), Capacity Margin (20), Load Accounting (15).

    Load workflows must be checked against the adopted local code edition, utility rules, and authority requirements.

  • Load Accounting 33

    Transparent connected-load and worksheet accounting workflows.

  • Capacity Margin 29

    Capacity, margin, and preliminary headroom screens.

  • Commercial Load 26

    Commercial and industrial connected-load workflows.

  • Residential Load 26

    Residential load line-item and service-planning workflows.

  • Demand Factor 23

    Explicit demand-factor inputs and load-accounting workflows.

  • Line Current 21

    Line-current and phase-model arithmetic workflows.

  • Equipment Review 16

    Equipment-data and nameplate review workflows.

  • Engineering Estimate 12

    Formula-backed estimates that require professional verification before final use.

  • Motor Output 7

    Motor and equipment output inputs used in load estimates.

  • Industrial Load 6

    Industrial equipment inventory and connected-load workflows.

  • Lighting Load 4

    Lighting load and connected lighting power workflows.

  • Backup Power 3

    Generator and backup-power planning workflows.

  • Power Factor 3

    Power-factor and apparent-power conversion workflows.

  • Connected Load 2

  • Field Verification 2

    Measured field data reduction and verification workflows.

  • Battery Storage 1

    Battery energy, runtime, and capacity estimation workflows.

  • Continuous Load 1

  • Ev Charging 1

  • Harmonics 1

    Harmonic-current and power-quality screening workflows.

  • Load Blocks 1

  • Voltage Drop 1

    Voltage-drop and conductor-length calculation workflows.

Review basis

Load workflows must be checked against the adopted local code edition, utility rules, equipment data, and authority requirements.

Everything under Load Calculations is a calculation from values you enter, not an approval. The pages here cite IEEE and NFPA 70 (NEC) among their basis, so confirm the edition adopted in your jurisdiction against the source text before relying on a number for design or installation.

Where to go next: Commercial And Industrial Loads and Residential Load And Service and the formula reference, all calculators, or printable worksheets for the same calculations.