The 12 calculators in Solar And Backup Power grouped into 8 sub-topics by the work each is built for. A calculator appears under every sub-topic it serves, so these groups overlap where the same page answers more than one question.

Backup Power

Generator and backup-power planning workflows.

Capacity Margin

Capacity, margin, and preliminary headroom screens.

Battery Storage

Battery energy, runtime, and capacity estimation workflows.

Load Accounting

Transparent connected-load and worksheet accounting workflows.

Equipment Review

Equipment-data and nameplate review workflows.

Engineering Estimate

Formula-backed estimates that require professional verification before final use.

Fuel Consumption

Fuel-burn and runtime calculations.

Line Current

Line-current and phase-model arithmetic workflows.

What this topic covers

About this category

12 calculators are grouped under Solar And Backup Power, and the work splits into Backup Power, Capacity Margin, Battery Storage, Load Accounting. Every page states the formula it applies, the inputs and units it expects, and the limits of the estimate, so a result can be checked against the adopted code edition and the equipment nameplate before it is used for a design decision.

Written for Electricians, Engineers, Estimators, Facility Teams, Inspectors, and Technicians.

Start with the topic that matches the job: Battery, Generator And Backup Power (6) and EV Charging And Electrical Infrastructure (6). Each topic page carries its own sub-topics, formula sheet, and review notes.

Basis cited across this topic: NFPA 70 (NEC) (4). Each calculator lists its own source citation and review dates on its page.

Formulas used in this category

The arithmetic the 12 calculators in Solar And Backup Power apply, in the order it is evaluated. These are calculation summaries, not code text — verify each against the source standard before design use. Full explanations for every topic are in the formula reference index.

Show formula sheet (12 calculators)
Backup Generator Sizing Calculator
  • \(P_{\mathrm{running}} = P_{\mathrm{critical}} + P_{\mathrm{essential}}\)
  • \(P_{\mathrm{start}} = P_{\mathrm{running}} + P_{\mathrm{motor\ start}} \times M_{\mathrm{start}}\)
  • \(P_{\mathrm{surge}} = P_{\mathrm{start}} \times \left(1 + \frac{R_{\%}}{100}\right)\)
  • \(S_{\mathrm{generator}} = \frac{P_{\mathrm{surge}}}{\mathrm{PF}}\)
Backup Load Priority Calculator
  • \(P_{\mathrm{priority}} = P_{\mathrm{critical}} + P_{\mathrm{essential}}\)
  • \(P_{\mathrm{reserved}} = P_{\mathrm{backup}} \times \frac{R_{\%}}{100}\)
  • \(P_{\mathrm{available}} = P_{\mathrm{backup}} - P_{\mathrm{reserved}}\)
  • \(P_{\mathrm{optional,\ supported}} = \min\left(P_{\mathrm{optional}},\ \max\left(P_{\mathrm{available}} - P_{\mathrm{priority}},0\right)\right)\)
Battery Bank Series Parallel Calculator
  • \(V_{\mathrm{bank}} = V_{\mathrm{battery}} \times N_{\mathrm{series}}\)
  • \(C_{\mathrm{bank}} = C_{\mathrm{battery}} \times N_{\mathrm{parallel}}\)
  • \(E_{\mathrm{nominal}} = V_{\mathrm{bank}} \times C_{\mathrm{bank}}\)
Battery Capacity Calculator
  • \(P_{\text{load}}=\text{load power},\quad t=\text{required runtime},\quad V_{\text{system}}=\text{nominal system voltage}\)
  • \(\mathrm{DoD}=\text{usable depth of discharge percent},\quad \eta=\text{system efficiency percent}\)
  • \(E_{\text{load}} = P_{\text{load}} \times t\)
  • \(f_{\text{usable}} = \frac{\mathrm{DoD}}{100} \times \frac{\eta}{100}\)
  • \(E_{\text{battery}} = \frac{E_{\text{load}}}{f_{\text{usable}}}\)
  • \(C_{\text{battery}} = \frac{E_{\text{battery}}}{V_{\text{system}}}\)
Battery Charge Time Calculator
  • \(Q_{\mathrm{available}} = C_{\mathrm{Ah}} \times \left(1-\frac{\mathrm{SoC}_{\mathrm{start}}}{100}\right)\)
  • \(I_{\mathrm{effective}} = I_{\mathrm{charge}} \times \frac{\eta_{\mathrm{charge}}}{100}\)
  • \(t_{\mathrm{charge}} = \frac{Q_{\mathrm{available}}}{I_{\mathrm{effective}}}\)
Battery Discharge Current Calculator
  • \(P_{\mathrm{DC}} = \frac{P_{\mathrm{load}}}{\eta}\)
  • \(I_{\mathrm{DC}} = \frac{P_{\mathrm{DC}}}{V_{\mathrm{battery}}}\)
  • \(P_{\mathrm{loss}} = P_{\mathrm{DC}} - P_{\mathrm{load}}\)
Battery Runtime Calculator
  • \(C_{\text{battery}}=\text{nominal battery capacity in Ah},\quad V_{\text{system}}=\text{nominal system voltage},\quad P_{\text{load}}=\text{load power}\)
  • \(\mathrm{DoD}=\text{usable depth of discharge percent},\quad \eta=\text{system efficiency percent}\)
  • \(E_{\text{nominal}} = C_{\text{battery}} \times V_{\text{system}}\)
  • \(E_{\text{usable}} = E_{\text{nominal}} \times \frac{\mathrm{DoD}}{100} \times \frac{\eta}{100}\)
  • \(t_{\text{runtime}} = \frac{E_{\text{usable}}}{P_{\text{load}}}\)
Generator Fuel Runtime Calculator
  • \(P_{\mathrm{avg}} = P_{\mathrm{rated}}\times\frac{L_{\mathrm{avg}}}{100}\)
  • \(r_{\mathrm{fuel}} = P_{\mathrm{avg}}\times e_{\mathrm{fuel}}\)
  • \(t_{\mathrm{runtime}} = \frac{G_{\mathrm{usable}}}{r_{\mathrm{fuel}}}\)
Generator Transfer Load Calculator
  • effective generator capacity = generator capacity x usable capacity factor / 100
  • reserved capacity = effective generator capacity x reserve percent / 100
  • available transfer capacity = effective generator capacity - reserved capacity
  • transfer margin = available transfer capacity - transfer load
Inverter Size Calculator
  • \(\text{Margin multiplier} = 1 + \frac{\text{margin (\%)}}{100}\)
  • \(\text{Continuous rating (W)} = \text{running watts} \times \text{margin multiplier}\)
  • \(\text{Surge rating (W)} = \text{surge watts} \times \text{margin multiplier}\)
  • \(\text{Apparent power (VA)} = \frac{\text{continuous rating (W)}}{\text{power factor}}\)
  • \(\text{Efficiency factor} = \frac{\text{efficiency (\%)}}{100}\)
  • \(\text{Estimated DC input (W)} = \frac{\text{continuous rating (W)}}{\text{efficiency factor}}\)
Residential Sump Pump Backup Runtime Calculator
  • \(E_{\mathrm{stored,Wh}} = V_{\mathrm{battery}} \times C_{\mathrm{Ah}}\)
  • \(E_{\mathrm{usable}} = E_{\mathrm{stored}} \times F_{\mathrm{usable}} \times \eta_{\mathrm{inverter}} \times (1 - F_{\mathrm{reserve}})\)
  • \(P_{\mathrm{avg}} = P_{\mathrm{running}} \times F_{\mathrm{duty}}\)
  • \(t_{\mathrm{runtime}} = \frac{E_{\mathrm{usable}}}{P_{\mathrm{avg}}}\)
  • \(\mathrm{Surge\ margin} = P_{\mathrm{surge\ limit}} - P_{\mathrm{starting}}\)
Solar Battery Size Calculator
  • \(\text{Autonomy load energy (kWh)} = \text{Daily energy (kWh/day)}\times\text{Autonomy (days)}\)
  • \(\text{Usable factor} = \frac{\text{Depth of discharge (\%)}}{100}\times\frac{\text{Round-trip efficiency (\%)}}{100}\)
  • \(\text{Base battery capacity (kWh)} = \frac{\text{Autonomy load energy}}{\text{Usable factor}}\)
  • \(\text{Required battery capacity (kWh)} = \text{Base battery capacity}\times\left(1+\frac{\text{Reserve (\%)}}{100}\right)\)
  • \(\text{Required battery capacity (Ah)} = \frac{\text{Required battery capacity (kWh)}\times1{,}000}{\text{System voltage (V)}}\)

Review basis

Backup-power workflows use entered assumptions and do not approve listed equipment, protection, transfer equipment, battery safety, utility interconnection, or code compliance.

Everything under Solar And Backup Power is a calculation from values you enter, not an approval. The pages here cite NFPA 70 (NEC) among their basis, so confirm the edition adopted in your jurisdiction against the source text before relying on a number for design or installation.

Where to go next: Battery, Generator And Backup Power and EV Charging And Electrical Infrastructure and the formula reference, all calculators, or printable worksheets for the same calculations.